+39 331 584 7291 [email protected] Mon-Fri 8:00-17:30 (CET)
Alarm Type Alarm Level Units Assigned

Alarm Type Alarm Level Units Assigned

Browse technical resources about specialty optical cables, hybrid cables, waterproof patch cords, MPO/MTP, AWG WDM, 800G transceivers, testers, outdoor power cabinets, DCI, smart grid and industrial o...

  • Courtyard wall vibration fiber optic alarm

    Courtyard wall vibration fiber optic alarm

    Highly reliable vibration fiber optic alarm system designed for 24/7 perimeter intrusion detection. Ideal for factory yards, residential communities, and commercial compounds. Two of the most widely deployed technologies for fence lines, buried perimeters, and walls are fibre-optic detectors and vibration sensors. Advanced adaptive signal processing along with certified SMS/VMS integration options ensure the. Long distance: Max 1 km each zone, realizing the overall prevention of large range and long distance. Installation methods: Buried, hanging net, buried wall. Communication mode: Dry. At Hikvision, we offer optical fiber products that use light waves and optical fibers to detect and respond to environmental changes precisely.


  • Why does an alarm sound when the temperature sensing cable is only connected to the terminal box

    Why does an alarm sound when the temperature sensing cable is only connected to the terminal box

    This usually means the DTS host cannot receive a valid optical signal from the sensing fiber. Possible causes include a broken optical fiber, disconnected jumper, wrong port connection, dirty connector, excessive bending, incorrect channel selection, or device startup failure. The Problem: When signal wires and power wires run together, the power wires can create electromagnetic interference (EMI). Example: Imagine a temperature sensor wire running alongside a motor's power cable. The sensor. Distributed Temperature Sensing (DTS) monitors temperature over long distances in cable corridors, pipelines, tunnels, tanks, plants, mines, and fire detection systems. While the two factors may seem minor compared to other threats, they can lead to false alarms, system failures, and even the inability to detect a real fire. Despite their reliability, users—whether engineers, technicians, or maintenance personnel—often encounter various. However, when a temperature reading goes awry, the humble thermocouple is often the first component to be blamed.

    [PDF Version]
  • Which outdoor constant temperature cabinet energy-saving type is better for customs declaration

    Which outdoor constant temperature cabinet energy-saving type is better for customs declaration

    Choose cabinet fans for mild climates with low heat and clean air to save energy and reduce costs. Provides precise temperature and humidity control. Offers moderate cooling by moving ambient air. By incorporating thermoelectric cooling modules into outdoor cabinets, designers can achieve precise temperature control with minimal moving parts, reducing maintenance requirements and increasing reliability in challenging outdoor environments. Built on three pillars — scientific material selection + intelligent thermal management +. According to different geographical environments, we have 3 different solutions: 1.


  • Campus network uses Japanese aluminum alloy cable tray racks rack type

    Campus network uses Japanese aluminum alloy cable tray racks rack type

    In the of buildings, a cable tray system is used to support insulated used for power distribution, control, and communication. Cable trays are used as an alternative to open wiring or systems, and are commonly used for cable management in commercial and industrial construction. They are especially useful in situations where changes to a wiring system are anticipated,.


  • What type of tool are fiber strippers

    What type of tool are fiber strippers

    Fiber strippers are precision tools that reliably and cleanly remove a defined length of coating (often 30–40 mm) from a fiber end so that the bare glass is exposed without scratching or nicking it. Let me explain the details of several commonly used fiber stripper types as follows! 1. In an industry where precision is not just a goal but a requirement, the quality of your stripping tool directly impacts signal integrity, network reliability, and overall. Fiber strippers and other fiber optic stripping tools with which you prepare your fibers for splicing. Jonard Tools is committed to manufacturing our products with premium-quality materials for all our tools including our fiber optic cable strippers. The precision required varies depending on the layer being removed. Several types of stripping tools are available, each designed for specific tasks and cable types.

    [PDF Version]
  • Type of fiber optic cable used for broadband

    Type of fiber optic cable used for broadband

    Cable Types: There are primarily two types of fiber optic cables: single-mode for long-range communication and multimode for medium-range. Choosing the right cable is not just about speed. It is about transmission distance. A fiber optic cable (frequently shortened to “fiber cable”) is a specialized transmission medium crafted to carry data as light pulses through ultra-thin strands of glass or plastic known as optical fibers. It offers high bandwidth, low signal loss, and resistance to electromagnetic interference (EMI), making it ideal for modern high-speed networks. Multimode is relatively less costly and works on shorter.


  • What is the normal optical attenuation level for a 20km optical module

    What is the normal optical attenuation level for a 20km optical module

    An acceptable dB loss is typically around 3. 5 dB/km at 1300 nm for standard multimode fibers. These values represent the industry standards for commonly used fiber. The maximum range is obtained by dividing the available budget by the attenuation per kilometer of cable: Maximum distance (km) = Available budget (dB) ÷ Cable attenuation (dB/km) − [Fixed losses / Cable attenuation] For an OS2 cable with an attenuation of 0,35 dB/km at 1310 nm, 4 connectors (4 ×. This guide outlines general best-practice guidelines for optical attenuation. Actual attenuation requirements will vary depending on the specific transmitter output power and receiver sensitivity of the optical modules in use. Note: The values presented are approximate and provided for reference. This document describes how to calculate the maximum attenuation for an optical fiber. There are no specific requirements for this document. Many factors cause fiber attenuation. The most fundamental parameter for optical fiber is geometry, since the dimensions of the fiber determine its ability to be spliced and terminated to other fibers.

    [PDF Version]
  • How to level the area around the distribution box

    How to level the area around the distribution box

    The solution to this problem is to repair the distribution cover. If it is uneven, it will need to be smoothed out. Also, consider correcting surface drainage around your property if. Governed by NEC 110. 26, these rules define the minimum Spaces about electrical equipment necessary for workers to perform tasks like inspection, maintenance, and replacement safely. The core components of this standard involve the Depth of working space, which varies based on the system's. Ever wonder how contractors level a distribution box, especially in rocky soil or when a drain field is oversaturated? This video explains how distribution boxes work, how to adjust water flow with speed levelers, and why evenly dispersing wastewater into drain fields is crucial. more. In industrial power distribution systems, cable distribution boxes (also known as power distributor boxes, distribution electrical boxes, or electrical power distribution boxes) are the core hub of power transmission, branching, and protection. Covers wiring, placement, standards, and expert tips for a compliant setup.

    [PDF Version]
  • What is the size of the circuit breaker for a level 3 distribution box

    What is the size of the circuit breaker for a level 3 distribution box

    The recommended size of circuit breaker is 1. Good to Know: The breaker and wire size calculations are valid for resistive loads. NEC breaker-size support reference for small-conductor limits, continuous-load review, standard breaker ratings, and when to use the breaker sizing calculator. Whether you're installing a new 30 amp breaker for an electric dryer or sizing a 40 amp breaker for an electric range, understanding the relationship between circuit breakers, wire sizes, and load requirements is essential for safe electrical work. MCBs usually follow a modular DIN rail size, commonly 18mm per pole. This comprehensive guide will walk.